Audit

The Audit View enables the construction of node-based graphs that show a dynamic visual flow diagram between objects in the ECU (channels, tables, maps etc).

Audit Audit

Audits graphs consist of nodes (the large square boxes in the diagram above). Each node has junctions which are the small circular attachments on the edges of the nodes. Junctions may be connected to other junctions by edges to indicate data flow.

There are multiple types of nodes.

  • Object Node - Displays an ECU based object (e.g. channel, option, table etc).
  • Submodule Node - Contains a diagram of its own (another node graph). Double clicking on a submodule will display its contents when the layout is locked.
  • Jump Module Node - Jumps to a submodule - this is like a shortcut to a submodule that exists somewhere else in the node graph hierarchy.
  • Notes Node - Displays notes to describe the graph in more detail.

At the top of the audit view is the module bar. This has navigation buttons to the left that enable traversing through the history of nodes that have been viewed during the current session. To the right of the navigation buttons, the current node is displayed and its parent graphs. Clicking on one of these will jump to that view. There is additionally a drop down menu for jumping to other locations in the graph tree.

View Properties

Properties editable via the properties editor.

PropertyScript IDDescription
Title title The title of the window.
Script ID id The scripting ID of the window. Can be used as an alternative to the title for searching for windows from scripts.
Tool Tip tooltip Window tool tip.
Display Units display_units_text Show units after the number on the view.
Display Units (Label) display_units_label Show units after the label on the view.
Prefix Text prefix_text Text to display before the value.
Postfix Text postfix_text Text to display after the value.
Limits limits Set up alarm limits for this gauge.
Show Value show_value
Show Label show_label
Label Font label_font
Value Font value_font
Value Height % value_height_percent A value of zero disables auto font size fitting if Value Height Max is set
Value Height Max [dp] value_height_max_dp Maximum font height of the value text, in device pixels
Label Height % label_height_percent
Label Height Max [dp] label_height_max_dp Maximum font height of the label, in device pixels
Label Text label_text
Label Align label_align
Label Vertical Align label_valign
Value Align value_align
Value Vertical Align value_valign
Low Limit Text low_limit_text
High Limit Text high_limit_text
Value Override Text value_text
Max length Text max_length_text Leave blank for auto
Background bg_colour Background colour
Text text_colour Text colour
Alarm Low Background alarm_low_bg_colour Alarm Lower Limit Background colour
Alarm Low Text alarm_low_text_colour Alarm Lower Limit Text colour
Alarm High Background alarm_high_bg_colour Alarm Upper Limit Background colour
Alarm High Text alarm_high_text_colour Alarm Upper Limit Text colour
Input Value parameter The source of the value that will be displayed by the gauge.
Update Rate update_rate Rate at which the input value is requested from the ECU.
Decimal Places decimal_places Set to -1 for auto