Audit
The Audit View enables the construction of node-based graphs that show a dynamic visual flow diagram between objects in the ECU (channels, tables, maps etc).


Audits graphs consist of nodes (the large square boxes in the diagram above). Each node has junctions which are the small circular attachments on the edges of the nodes. Junctions may be connected to other junctions by edges to indicate data flow.
There are multiple types of nodes.
- Object Node - Displays an ECU based object (e.g. channel, option, table etc).
- Submodule Node - Contains a diagram of its own (another node graph). Double clicking on a submodule will display its contents when the layout is locked.
- Jump Module Node - Jumps to a submodule - this is like a shortcut to a submodule that exists somewhere else in the node graph hierarchy.
- Notes Node - Displays notes to describe the graph in more detail.
At the top of the audit view is the module bar. This has navigation buttons to the left that enable traversing through the history of nodes that have been viewed during the current session. To the right of the navigation buttons, the current node is displayed and its parent graphs. Clicking on one of these will jump to that view. There is additionally a drop down menu for jumping to other locations in the graph tree.
View Properties
Properties editable via the properties editor.
Property | Script ID | Description |
---|---|---|
Title | title |
The title of the window. |
Script ID | id |
The scripting ID of the window. Can be used as an alternative to the title for searching for windows from scripts. |
Tool Tip | tooltip |
Window tool tip. |
Display Units | display_units_text |
Show units after the number on the view. |
Display Units (Label) | display_units_label |
Show units after the label on the view. |
Prefix Text | prefix_text |
Text to display before the value. |
Postfix Text | postfix_text |
Text to display after the value. |
Limits | limits |
Set up alarm limits for this gauge. |
Show Value | show_value |
|
Show Label | show_label |
|
Label Font | label_font |
|
Value Font | value_font |
|
Value Height % | value_height_percent |
A value of zero disables auto font size fitting if Value Height Max is set |
Value Height Max [dp] | value_height_max_dp |
Maximum font height of the value text, in device pixels |
Label Height % | label_height_percent |
|
Label Height Max [dp] | label_height_max_dp |
Maximum font height of the label, in device pixels |
Label Text | label_text |
|
Label Align | label_align |
|
Label Vertical Align | label_valign |
|
Value Align | value_align |
|
Value Vertical Align | value_valign |
|
Low Limit Text | low_limit_text |
|
High Limit Text | high_limit_text |
|
Value Override Text | value_text |
|
Max length Text | max_length_text |
Leave blank for auto |
Background | bg_colour |
Background colour |
Text | text_colour |
Text colour |
Alarm Low Background | alarm_low_bg_colour |
Alarm Lower Limit Background colour |
Alarm Low Text | alarm_low_text_colour |
Alarm Lower Limit Text colour |
Alarm High Background | alarm_high_bg_colour |
Alarm Upper Limit Background colour |
Alarm High Text | alarm_high_text_colour |
Alarm Upper Limit Text colour |
Input Value | parameter |
The source of the value that will be displayed by the gauge. |
Update Rate | update_rate |
Rate at which the input value is requested from the ECU. |
Decimal Places | decimal_places |
Set to -1 for auto |