PARAMTBL
Parameter tables are similar to tables but use live parameter data to fill the table.
A parameter table is defined with a name, axis start and offset labels, an optional axis parameter to determine the current site and a list of parameters defining the value at each site.
A parameter table is defined as follows:
| Field Name | Definition |
|---|---|
| PARAMTBL | This is entered as is and defines the values as a parameter table. |
| Name | Defines the name of the parameter table. This is displayed in selection menus and at the top of the table when displayed. |
| Axis Parameter | This is the name of the parameter used for the axis of a table (or x axis of a map). In some tables (e.g. battery compensation table) the parameter is used to determine the current position in the table. In others (e.g. speed table) the parameter is used by the maps that use the table as their axis. This name may also be the name of a table used for the axis of a table or map (as referred to in the speed table example). Note tables take precedence over parameters. You should avoid duplicating names of parameters, options and tables for values that are referenced by this field. If such a conflict exists, Ginmake will warn you. |
| Axis Units | The units for the axis (or x axis of the map). (May also be user scalar units as per field 2.). Defaults to an empty string. |
| Start | The axis value of the first step. This is an integer value. If preceded by a ‘*’ the subsequent real value is the first step value. Defaults to 0. Alternatively, this may be the name of an option if a table has not been used for the axis parameter. The name may optionally be placed in brackets. |
| Offset | The offset of each subsequent axis site from the start axis value. This is an integer value. If preceded by a ‘*’ the subsequent real value is the offset. Defaults to 1. Alternatively, this may be the name of an option if a table has not been used for the axis parameter. The name may optionally be placed in brackets. |
| Parameter[1] | Defines the parameter used to determine the value of the first site. This is followed by the names of the parameters defining the subsequent site values. Ginmake 1.78+ May also use a range expression here. There are 2 possible formats 1) A range of parameters separated by an ellipsis, which will include all parameters in declaration order between (and including) the start and end values given. <param[1]>…<param[N]> e.g. TPER00…TPER31 2) A printf style format expression, preceeded by an ellipsis, the bounds for the expanded range are placed in the next two fields following this field. e.g. [PARAMTBL, |
| Parameter[2] | [Optional] Second parameter in the table. |
| Parameter[n] | [Optional] Nth parameter in the table. |