VIEWRANGE
Supported by Ginmake 1.24 and later, Gin file version 3.21
This is similar to VALIDRANGE but sets up a default range for views in the user interface. This can be useful if the range normally used is only a small subset of the total possible range. This is a soft limit – the user may specify values outside of this range. For ‘strong’ limits, use VALIDRANGE or HARDLIMITS.
e.g.
1// [Rad Fan 1,,OL3,,o,2,i,,][VIEWRANGE,1,100]
Values are RAW unscaled values.
Type specifiers may be used. Useful if the value cannot be reasonably represented using a 32bit signed integer.
To specify VIEWRANGE in physical (scaled) values, use LIMITS.
For A2L output, VIEWRANGE sets the object’s lower and upper limits. Raw values
are converted to physical values, except for enumerations, which use raw values.
For example, [VIEWRANGE,-1000,1000] with a *0.1 scalar exports limits of
-100 and 100.