Screen Selector

Overview

The Screen Selector channel is derived from an analogue input (depending on the type of module).

It uses a lookup table that is pre-calibrated for a 12 position switch using 1k resistors.

If you have used a different page select switch, the lookup table may need to be recalibrated.

CAN Page Select

If page select is being done via CAN or a button press, the page select input can be used as an analogue input (shown as A00 Raw).

To prevent the input also changing pages, edit the Screen Selector lookup table; set the first row to have an input of 0 and an output of 0 and the seconds row to have an input of 4096 and an output of 0.