Distance Countdown Channel
Overview
Distance Countdown Factor channels allow a programmable distance count-down value to be created that can be linked into the events system to allow end users to set a new value on the display itself and reset the countdown value with an event.


Settings
Initial Value
When a Reset event is received, the output shall be reset to Initial Value.
Reset Value
If Reset Value is checked then the display will use this value whenever a new setup has been programmed.
If the output has not been added to the monitor page, then the output will be reset to this value whenever it is not shown.
Resolution
This is the amount the value is changed by in response to the Increase and Decrease events.
Events
See also: Events Tab
Increase
Configures the event for increasing the Initial Value by the Resolution value.
Decrease
Configures the event for decreasing the Initial Value by the Resolution value.
Reset
Configures the event for resetting the output value to Initial Value.
Supported By Displays
Display | Supported? |
---|---|
CD34 | Yes |
LDS4 | Yes |
CD32 | Yes |
LDS35 | No |
LDS35_L | No |
CD6-43 | Yes |
GLW-43 | Yes |