Case Channel

Overview

Checks through a list of input channels until a non-zero (true) input is found and outputs a value corresponding to that input.

Case Channel Editor Case Channel Editor

Conditions

The condition list is in priority order - highest priority first; the case channel checks each Condition in list order in turn until a true condition (i.e. the value of the output is greater than 0) is found. This then results in the corresponding Output Value from the channel.

The case sensor is useful for making an output for use as the selector input in a bitmap selector.

Use the Add and Delete buttons to the bottom right of the list to add or remove rows from the list.

The priority of items may be adjusted with the Up and Down buttons.

Supported By Displays

DisplaySupported?
CD34 Yes
LDS4 Yes
CD32 Yes
LDS35 Yes
LDS35_L Yes
CD6-43 Yes
GLW-43 Yes