Calibration Factor Channel

Overview

Calibration Factor channels allow a programmable value to be created that can be linked into the events system to allow end users to set a new value on the display itself.

This can be used as a calibration factor or for storing initial fuel values for example.

Calibration Factor Channel Editor Calibration Factor Channel Editor

Settings

Initial Value

The display will use this value whenever a new setup has been programmed.

If the output has not been added to the monitor page, then the output will be reset to this value whenever it is not shown.

Always use initial value at startup

If “Always use initial value at startup” is checked then the calibration factor will not be saved in non-volatile memory during power-off of the display.

If the value should be persistent when the display is switched off, then the output MUST be added to the Monitored Channels .

Resolution

This is the amount the value is changed by in response to the Increase and Decrease events.

Apply Limits

If ticked then the display prevents the value from exceeding the Min Value or Max Value limits.

Wraparound

If limits are specified then the Wraparound option is available. Check Wraparound to make the calibration value go back to Min Value after increasing the value beyond Max Value (and also in the opposite direction).

Events

See also: Events Tab

Increase

Configures the event for increasing the calibration factor by the Resolution value.

Decrease

Configures the event for decreasing the calibration factor by the Resolution value.

Reset

Configures the event for resetting the calibration factor value to Initial Value.

Supported By Displays

DisplaySupported?
CD34 Yes
LDS4 Yes
CD32 Yes
LDS35 No
LDS35_L No
CD6-43 Yes
GLW-43 Yes